VisGuard 2 Extractive

Visibility Monitor
VisGuard 2 Extractive

The VisGuard measures the scattered light intensity of a sample drawn into the instrument. Filtered purge air is fed through the flow cell, thus enveloping the sample in a protective shroud of clean air. This effectively keeps the optics clean. Installations are either in the tunnel cavity/niches (in-situ) respectively using extractive sampling away from the cavity. An optional sample heater eliminates the influence of any mist effects.

Advantages

  • Continuous monitoring of oil mist concentration using scattered light principle
  • Easy to service, high sensitivity, stability and accuracy
  • A special sample flow concept entirely eliminates the danger of flow cell contamination
Download brochure

Technical data

Nominal range
0 .. 100 PLA (Polystyrol-Latex-Aerosols)
0 .. 3'000 mE/m
Protection class
IP66 (only with mounted protection caps)
Enclosure
Stainless steel 1.4435 / 1.4571
Measuring principle
30° scattered light
Operation voltage
24 VDC
Weight
5 kg
Power consumption
1 W
Option: heater 10 W
Dimensions
approx. Ø 209 x 254 mm
Resolution
0.001 mE/m
Ambient temperature
-30 °C .. +55 °C
Ambient humidity
0 .. 100 % rel. Humidity
Wavelength
880 nm
Connection box SIPORT 2
  • Power supply: 100 .. 240 VAC; 47 .. 63 Hz
  • Power input: max. 25 W / 45 VA
  • Protection: IP66
  • Enclosure: Polyester, fibre glass reinforced
  • Weight: 1.3 kg
  • Dimensions: approx. 220 x 155 x 91 mm
  • Modules for SIPORT 2
  • Interface Module Profibus DP
  • Interface Module Modbus RTU
  • Interface Module PowerRel:
    - 2 x 0/4 .. 20 mA, max. 500 Ω, galvanic separated
    - 3 x Semiconductor relays max. 30 V, max. 0.12 A, Ron max. 25 Ω
  • Hand-held control unit
    SICON-C for SIPORT 2:
    Graphics TFT with touch operation
    Conformities
    ASTRA «Guideline – Ventilation in road tunnels (2008)»
    RABT (2006)
    RVS 09.02.22
    Download data

    Downloads

    Preview Title Type

    Download