AquaDMS

Test 2

Advantages

  • Complete, pre-mounted measuring panel: mounting – water connection – measure
  • Stabilized water flow
  • Fast results, measurement is directly made in the medium
  • Automated, patented sensor cleaning
  • Configuration without or with pH compensation
  • No zero drift
  • Control unit with touch screen
  • SD card for loading and saving setup, saving of diagnosis data and software updates
Download brochure

Technical data

Measuring cell
  • Sample connection: Tube, inside Ø6 mm, outside max. Ø8 mm
  • Flow: 35 .. 400 l/h
  • Pressure: 6 bars @ 20 °C
  • Sample temperature: 0 .. 50 °C
  • conductivity: > 50µS/cm
Double gold & graphite sensor
  • Measuring principle: Potentiostatic measurement
  • Nominal range:
    • Free Chlorine 0 .. 20 mg/l
    • Chlorine Dioxide 0 .. 20 mg/l
    • Ozone 0 .. 10 mg/l
    • Temperature: -30 .. +140° C
  • Scale ranges:
    • 0 .. 1'000 µg/l; 0 .. 5 / 10 / 20 mg/l Cl2 or ClO2
    • 0 .. 1'000 µg/l; 0 .. 5 / 10 mg/l O3
  • Accuracy: ±2% of measuring range limit
  • Resolution: 0.01 mg/l
  • pH range: 6 .. 9 (free Chlorine: 6 .. 8 constant)
Double platinum sensor
  • Measuring principle: Potentiostatic measurement
  • Nominal range:
    • Hydrogen Peroxide 0 .. 30 mg/l
    • Temperature -30 .. +140° C
  • Scale range: Fix, 0 .. 30 mg/l H2O2
  • Accuracy: ±2% of measuring range limit
  • Resolution: 0.01 mg/l
  • pH range: 6 .. 9
Operation

Intelligent control system

  • Housing: ABS
  • Operation & display: Monochrome touch screen, 90 x 50 mm
  • Protection: IP65
  • Supply voltage:
    • Without pH compensation: 85 .. 250 VAC, +6/-10%; 40 .. 60 Hz
    • With pH compensation: 85 .. 265 VAC, 50 .. 60 Hz
  • Power input: < 10 VA
  • Outputs (depending on product variant):
    • 1/5 x 0/4 .. 20 mA, max. burden 500 Ω, galv. isolated
    • 1/4x relay, potential free contact 6A, 250 V, max. 550VA, freely configurable
    • Automatic sensor cleaning
  • Input: 1 x digital, function selectable, (NO/NC)
  • Storage medium: SD card up to 2GB – industrial standard
  • Ambient temperature: 0 .. 50° C
  • Ambient humidity: < 90% relative humidity @ 40° C (non-condensing)
Download data

Downloads

Preview Title Type

Download